Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 449
Filtrar
3.
Ultrasound Obstet Gynecol ; 63(4): 446-456, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38197327

RESUMO

OBJECTIVE: To determine the diagnostic accuracy of prenatal ultrasound in detecting coarctation of the aorta (CoA). METHODS: An individual participant data meta-analysis was performed to report on the strength of association and diagnostic accuracy of different ultrasound signs in detecting CoA prenatally. MEDLINE, EMBASE and CINAHL were searched for studies published between January 2000 and November 2021. Inclusion criteria were fetuses with suspected isolated CoA, defined as ventricular and/or great vessel disproportion with right dominance on ultrasound assessment. Individual participant-level data were obtained by two leading teams. PRISMA-IPD and PRISMA-DTA guidelines were used for extracting data, and the QUADAS-2 tool was used for assessing quality and applicability. The reference standard was CoA, defined as narrowing of the aortic arch, diagnosed after birth. The most commonly evaluated parameters on ultrasound, both in B-mode and on Doppler, constituted the index test. Summary estimates of sensitivity, specificity, diagnostic odds ratio (DOR) and likelihood ratios were computed using the hierarchical summary receiver-operating-characteristics model. RESULTS: The initial search yielded 72 studies, of which 25 met the inclusion criteria. Seventeen studies (640 fetuses) were included. On random-effects logistic regression analysis, tricuspid valve/mitral valve diameter ratio > 1.4 and > 1.6, aortic isthmus/arterial duct diameter ratio < 0.7, hypoplastic aortic arch (all P < 0.001), aortic isthmus diameter Z-score of < -2 in the sagittal (P = 0.003) and three-vessel-and-trachea (P < 0.001) views, pulmonary artery/ascending aorta diameter ratio > 1.4 (P = 0.048) and bidirectional flow at the foramen ovale (P = 0.012) were independently associated with CoA. Redundant foramen ovale was inversely associated with CoA (P = 0.037). Regarding diagnostic accuracy, tricuspid valve/mitral valve diameter ratio > 1.4 had a sensitivity of 72.6% (95% CI, 48.2-88.3%), specificity of 65.4% (95% CI, 46.9-80.2%) and DOR of 5.02 (95% CI, 1.82-13.9). The sensitivity and specificity values were, respectively, 75.0% (95% CI, 61.1-86.0%) and 39.7% (95% CI, 27.0-53.4%) for pulmonary artery/ascending aorta diameter ratio > 1.4, 47.8% (95% CI, 14.6-83.0%) and 87.6% (95% CI, 27.3-99.3%) for aortic isthmus diameter Z-score of < -2 in the sagittal view and 74.1% (95% CI, 58.0-85.6%) and 62.0% (95% CI, 41.6-78.9%) for aortic isthmus diameter Z-score of < -2 in the three-vessel-and-trachea view. Hypoplastic aortic arch had a sensitivity of 70.0% (95% CI, 42.0-88.6%), specificity of 91.3% (95% CI, 78.6-96.8%) and DOR of 24.9 (95% CI, 6.18-100). The diagnostic yield of prenatal ultrasound in detecting CoA did not change significantly when considering multiple categorical parameters. Five of the 11 evaluated continuous parameters were independently associated with CoA (all P < 0.001) but all had low-to-moderate diagnostic yield. CONCLUSIONS: Several prenatal ultrasound parameters are associated with an increased risk for postnatal CoA. However, diagnostic accuracy is only moderate, even when combinations of parameters are considered. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Coartação Aórtica , Canal Arterial , Gravidez , Feminino , Humanos , Coartação Aórtica/diagnóstico por imagem , Ultrassonografia Pré-Natal , Aorta/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Canal Arterial/diagnóstico por imagem , Estudos Retrospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38279964

RESUMO

OBJECTIVE: Fetuses with late growth restriction (FGR) have a higher risk of sub-optimal neurocognitive performance after birth. Previous studies have reported that impaired brain and cortical development can start in utero. The primary aim of this study was to report midline structures and cortical development in fetuses with late growth restriction according to its severity; the secondary aim was to elucidate whether the severity of FGR, as defined by the presence of abnormal Doppler findings, plays a role in affecting brain growth and maturation. METHODS: Prospective cross-sectional study including fetuses with late FGR undergoing neurosonography between 32 and 34 weeks of gestation. Midline structures (corpus callosum (CC) and cerebellar vermis (CV) length) and cortical development, including the depth of Sylvian (SF), parieto-occipital (POF) and calcarine (CF) were compared between FGR, small (SGA) and appropriate for gestational age (AGA) fetuses, defined upon the Delphi criteria. Sub-group analysis according to the severity of FGR (normal vs abnormal fetal Dopplers) was also performed. Univariate analysis was used to analyze the data. RESULTS: 52 FGR with normal, 60 with abnormal Dopplers, 64 SGA and 100 AGA fetuses were included in the analysis. SGA and FGR fetuses showed significant differences in absolute values of CC (median (interquartile range) control 43.47 (28.9-56.05), vs SGA 41.85 (27.82-51.79), vs FGR ND 38.54 (29.12-50.53), vs FGR AD 31.72 (23.8-40.19) K= 26.68; p<0.0001), CV (control 24.85 (17.55-29.21), SGA K=16.71; p=0.0008), SF (control 14.52 (10.65-16.76) vs SGA 12.71 (9.8-15.10) vs FGR ND 11.93 (9.12-13.43) VS FGR A 8.30 (6.72-10.33) K=75.82; p<0.0001), POF (control 8.56 (6.31-11.09) vs SGA 8.11 (5.58-10.43) vs FGR ND 7.81 (6.14-9.29) vs FGR AD 6.56 (4.22-7.99), K=45.06; p<0.0001) and CF ( control 9.27 (6.70-11.45) vs SGA 8.23 (5.67-10.65) vs FGR ND 7.68 (5.22-9.41) vs FGR AD 6.26 (4.48-7.19) K=46.14; p<0.0001) when compared to AGA controls with a progressive reduction across groups. When neurosonographic variables were corrected for fetal HC values, significant difference in the length of CC, SF, POF and CF but CV were observed only in FGR fetuses with abnormal Doppler when compared to AGA controls. CONCLUSIONS: Late onset small fetuses showed shorter CC length and a delayed cortical development when compared to control. After controlling for HC size these differences remain significant only in FGR fetuses with abnormal Dopplers. These findings support the existence of a link between brain development and impaired placental function. This article is protected by copyright. All rights reserved.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37955999

RESUMO

The recovery of motor functions after stroke is fostered by the functional integration of large-scale brain networks, including the motor network (MN) and high-order cognitive controls networks, such as the default mode (DMN) and executive control (ECN) networks. In this paper, electroencephalography signals are used to investigate interactions among these three resting state networks (RSNs) in subacute stroke patients after motor rehabilitation. A novel metric, the O-information rate (OIR), is used to quantify the balance between redundancy and synergy in the complex high-order interactions among RSNs, as well as its causal decomposition to identify the direction of information flow. The paper also employs conditional spectral Granger causality to assess pairwise directed functional connectivity between RSNs. After rehabilitation, a synergy increase among these RSNs is found, especially driven by MN. From the pairwise description, a reduced directed functional connectivity towards MN is enhanced after treatment. Besides, inter-network connectivity changes are associated with motor recovery, for which the mediation role of ECN seems to play a relevant role, both from pairwise and high-order interactions perspective.


Assuntos
Mapeamento Encefálico , Acidente Vascular Cerebral , Humanos , Imageamento por Ressonância Magnética , Encéfalo , Causalidade
8.
Ultrasound Obstet Gynecol ; 62(2): 219-225, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36905679

RESUMO

OBJECTIVE: The prediction of adverse perinatal outcomes in low-risk pregnancies is poor, mainly owing to the lack of reliable biomarkers. Uterine artery (UtA) Doppler is closely associated with placental function and may facilitate the peripartum detection of subclinical placental insufficiency. The objective of this study was to evaluate the association of mean UtA pulsatility index (PI) measured in early labor with obstetric intervention for suspected intrapartum fetal compromise and adverse perinatal outcome in uncomplicated singleton term pregnancies. METHODS: This was a prospective multicenter observational study conducted across four tertiary maternity units. Low-risk term pregnancies with spontaneous onset of labor were included. The mean UtA-PI was recorded between uterine contractions in women admitted for early labor and converted into multiples of the median (MoM). The primary outcome of the study was the occurrence of obstetric intervention, i.e. Cesarean section or instrumental delivery, for suspected intrapartum fetal compromise. Secondary outcomes were the occurrence of adverse perinatal outcomes, including 5-min Apgar score < 7, low cord arterial pH, raised cord arterial base excess, admission to the neonatal intensive care unit (NICU) and postnatal diagnosis of small-for-gestational-age fetus. Composite adverse perinatal outcome was defined as the occurrence of at least one of the following: acidemia in the umbilical artery, defined as pH < 7.10 and/or base excess > 12 mmol/L, 5-min Apgar score < 7 or admission to the NICU. RESULTS: Overall, 804 women were included, of whom 40 (5.0%) had abnormal mean UtA-PI MoM. Women who had an obstetric intervention for suspected intrapartum fetal compromise were more frequently nulliparous (72.2% vs 53.6%; P = 0.008), had a higher frequency of increased mean UtA-PI MoM (13.0% vs 4.4%; P = 0.005) and had a longer duration of labor (456 ± 221 vs 371 ± 192 min; P = 0.01). On logistic regression analysis, only increased mean UtA-PI MoM (adjusted odds ratio (aOR), 3.48 (95% CI, 1.43-8.47); P = 0.006) and parity (aOR, 0.45 (95% CI, 0.24-0.86); P = 0.015) were independently associated with obstetric intervention for suspected intrapartum fetal compromise. Increased mean UtA-PI MoM was associated with a sensitivity of 0.13 (95% CI, 0.05-0.25), specificity of 0.96 (95% CI, 0.94-0.97), positive predictive value of 0.18 (95% CI, 0.07-0.33), negative predictive value of 0.94 (95% CI, 0.92-0.95), positive likelihood ratio of 2.95 (95% CI, 1.37-6.35) and negative likelihood ratio of 0.91 (95% CI, 0.82-1.01) for obstetric intervention for suspected intrapartum fetal compromise. Pregnancies with increased mean UtA-PI MoM also showed a higher incidence of birth weight < 10th percentile (20.0% vs 6.7%; P = 0.002), NICU admission (7.5% vs 1.2%; P = 0.001) and composite adverse perinatal outcome (15.0% vs 5.1%; P = 0.008). CONCLUSION: Our study, conducted in a cohort of low-risk term pregnancies enrolled in early spontaneous labor, showed an independent association between increased mean UtA-PI and obstetric intervention for suspected intrapartum fetal compromise, albeit with moderate capacity to rule in, and poor capacity to rule out, this condition. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Cesárea , Resultado da Gravidez , Recém-Nascido , Gravidez , Feminino , Humanos , Resultado da Gravidez/epidemiologia , Terceiro Trimestre da Gravidez , Artéria Uterina/diagnóstico por imagem , Estudos Prospectivos , Placenta/irrigação sanguínea , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Fluxo Pulsátil , Artérias Umbilicais/diagnóstico por imagem
9.
NPJ Parkinsons Dis ; 9(1): 34, 2023 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-36871045

RESUMO

To compare the diagnostic accuracy of the immunofluorescence (IF) technique and aSyn-seed amplification assay (aSyn-SAA) of skin and cerebrospinal fluid (CSF) in disclosing pathological α-syn in idiopathic idiopathic REM sleep behavior disorder (iRBD) as early phase of a synucleinopathy. We prospectively recruited 41 patients with iRBD and 40 matched clinical controls including RBD associated with type 1 Narcolepsy (RBD-NT1, 21 patients), iatrogenic causes (2 pt) or OSAS (6 pt) and 11 patients with peripheral neuropathies. IF from samples taken by skin biopsy and aSyn-SAA from skin and CSF samples were analysed blinded to the clinical diagnosis. IF showed a good diagnostic accuracy (89%) that was lower in the case of skin and CSF-based aSyn-SAA (70% and 69%, respectively) because of a lower sensitivity and specificity. However, IF showed a significant agreement with CSF aSyn-SAA. In conclusion, our data may favor the use of skin biopsy and aSyn-SAA as diagnostic tools for a synucleinopathy in iRBD.

10.
Ultrasound Obstet Gynecol ; 61(1): 93-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35767709

RESUMO

OBJECTIVE: To evaluate the relationship between the fetal head-circumference-to-maternal-height (HC/MH) ratio measured shortly before delivery and the occurrence of Cesarean section (CS) for labor dystocia. METHODS: This was a multicenter prospective cohort study involving four tertiary maternity hospitals. An unselected cohort of women with a singleton fetus in cephalic presentation, at a gestational age beyond 36 + 0 weeks and without any contraindication for vaginal delivery, was enrolled between September 2020 and November 2021. The MH and fetal HC were measured on admission of the patient to the labor ward. The primary outcome of the study was the performance of the HC/MH ratio in the prediction of CS for labor dystocia. Women who underwent CS for any indication other than failed labor progression, including fetal distress, were excluded from the final analysis. RESULTS: A total of 783 women were included in the study. Vaginal delivery occurred in 744 (95.0%) women and CS for labor dystocia in 39 (5.0%). CS for labor dystocia was associated with shorter MH (mean ± SD, 160.4 ± 6.6 vs 164.5 ± 6.3 cm; P < 0.001), larger fetal HC (339.6 ± 9.5 vs 330.7 ± 13.0 mm; P < 0.001) and a higher HC/MH ratio (2.12 ± 0.11 vs 2.01 ± 0.10; P < 0.001) compared with vaginal delivery. Multivariate logistic regression analysis showed that the HC/MH ratio was associated independently with CS for labor dystocia (adjusted odds ratio, 2.65 (95% CI, 1.85-3.79); P < 0.001). The HC/MH ratio had an area under the receiver-operating-characteristics curve of 0.77 and an optimal cut-off value for discriminating between vaginal delivery and CS for labor dystocia of 2.09, which was associated with a sensitivity of 0.62 (95% CI, 0.45-0.77), specificity of 0.79 (95% CI, 0.76-0.82), positive predictive value of 0.13 (95% CI, 0.09-0.19) and negative predictive value of 0.98 (95% CI, 0.96-0.99). CONCLUSIONS: In a large cohort of unselected pregnancies, the HC/MH ratio performed better than did fetal HC and MH alone in identifying those cases that will undergo CS for labor dystocia, albeit with moderate predictive value. The HC/MH ratio could assist in the evaluation of women at risk for CS for labor dystocia. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Distocia , Trabalho de Parto , Gravidez , Feminino , Humanos , Lactente , Masculino , Cesárea , Estudos Prospectivos , Ultrassonografia Pré-Natal
11.
Ultrasound Obstet Gynecol ; 61(1): 67-73, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36056700

RESUMO

OBJECTIVE: To investigate the role of fetal brain magnetic resonance imaging (MRI) in detecting associated anomalies in fetuses with congenital cytomegalovirus (CMV) infection and normal neurosonography. METHODS: This was a multicenter, retrospective cohort study of patients examined between 2012 and 2021 in 11 referral fetal medicine centers in Italy. Inclusion criteria were fetuses with congenital CMV infection diagnosed by polymerase chain reaction analysis of amniotic fluid, pregnancies that underwent detailed multiplanar ultrasound assessment of the fetal brain as recommended by the International Society of Ultrasound in Obstetrics and Gynecology, maternal age ≥ 18 years, normal fetal karyotype and MRI performed within 3 weeks after the last ultrasound examination. The primary outcome was the rate of central nervous system (CNS) anomalies detected exclusively on MRI and confirmed after birth or autopsy in fetuses with a prenatal diagnosis of congenital CMV infection and normal neurosonography at diagnosis. Additional CNS anomalies were classified into anomalies of the ventricular and the periventricular zone, intracranial calcifications in the basal ganglia or germinal matrix, destructive encephalopathy in the white matter, malformations of cortical development, midline anomalies, posterior fossa anomalies and complex brain anomalies. We evaluated the relationship between the incidence of structural CNS malformations diagnosed exclusively on fetal MRI and a number of maternal and gestational characteristics. Univariate and multivariate logistic regression analyses were used to identify and adjust for potential independent predictors of the MRI diagnosis of fetal anomalies. RESULTS: The analysis included 95 fetuses with a prenatal diagnosis of congenital CMV infection and normal neurosonography referred for prenatal MRI. The rate of structural anomalies detected exclusively at fetal MRI was 10.5% (10/95). When considering the type of anomaly, malformations of cortical development were detected on MRI in 40.0% (4/10) of fetuses, destructive encephalopathy in 20.0% (2/10), intracranial calcifications in the germinal matrix in 10.0% (1/10) and complex CNS anomalies in 30.0% (3/10). On multivariate logistic regression analysis, only CMV viral load in the amniotic fluid, expressed as a continuous variable (odds ratio (OR), 1.16 (95% CI, 1.02-1.21); P = 0.02) or categorical variable (> 100 000 copies/mL) (OR, 12.0 (95% CI, 1.2-124.7); P = 0.04), was independently associated with the likelihood of detecting fetal anomalies on MRI. Associated anomalies were detected exclusively at birth and missed by both prenatal neurosonography and fetal MRI in 3.8% (3/80) of fetuses with congenital CMV infection. CONCLUSIONS: Fetal brain MRI can detect additional anomalies in a significant proportion of fetuses with congenital CMV infection and negative neurosonography. Viral load in the amniotic fluid was an independent predictor of the risk of associated anomalies in these fetuses. The findings of this study support a longitudinal evaluation using fetal MRI in congenital CMV infection, even in cases with negative neurosonography at diagnosis. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Encefalopatias , Doenças do Sistema Nervoso Central , Infecções por Citomegalovirus , Malformações do Desenvolvimento Cortical , Gravidez , Recém-Nascido , Feminino , Humanos , Adolescente , Ultrassonografia Pré-Natal/métodos , Estudos Retrospectivos , Diagnóstico Pré-Natal/métodos , Infecções por Citomegalovirus/diagnóstico por imagem , Infecções por Citomegalovirus/congênito , Imageamento por Ressonância Magnética/métodos , Líquido Amniótico , Doenças do Sistema Nervoso Central/complicações
13.
Artigo em Inglês | MEDLINE | ID: mdl-36085760

RESUMO

Isolated effective coherence (iCoh) is a measure of neural causal functional connectivity from EEG signals that was proven to overperform the Generalized Partial Directed Coherence (gPDC). However, iCoh sensitivity in the identification of reliable functional neural connections with respect to random links was not investigated. This study aims to compare the sensitivity of iCoh and gPDC with a statistical surrogates' approach. The cerebral motor network topology of a cohort of subjects in sub-acute stage after stroke was investigated. iCoh showed enhanced statistical discriminative power of the relevant connections within the motor network with respect to gPDC. This property influenced the assessment of ipsilesional intra-hemispheric topographic variations occurring in the population after a physical rehabilitation program.


Assuntos
Benchmarking , Acidente Vascular Cerebral , Causalidade , Eletroencefalografia , Humanos , Acidente Vascular Cerebral/diagnóstico
14.
Ultrasound Obstet Gynecol ; 60(5): 632-639, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35638182

RESUMO

OBJECTIVE: To describe the incidence, clinical features and perinatal outcome of late-onset fetal growth restriction (FGR) associated with genetic syndrome or aneuploidy, structural malformation or congenital infection. METHODS: This was a retrospective multicenter cohort study of patients who attended one of four tertiary maternity hospitals in Italy. We included consecutive singleton pregnancies between 32 + 0 and 36 + 6 weeks' gestation with either fetal abdominal circumference (AC) or estimated fetal weight < 10th percentile for gestational age or a reduction in AC of > 50 percentiles from the measurement at an ultrasound scan performed between 18 and 32 weeks. The study group consisted of pregnancies with late-onset FGR and a genetic syndrome or aneuploidy, structural malformation or congenital infection (anomalous late-onset FGR). The presence of congenital anomalies was ascertained postnatally in neonates with abnormal findings on antenatal investigation or detected after birth. The control group consisted of pregnancies with structurally and genetically normal fetuses with late-onset FGR. Composite adverse perinatal outcome was defined as the presence of at least one of stillbirth, 5-min Apgar score < 7, admission to the neonatal intensive care unit (NICU), need for respiratory support at birth, neonatal jaundice and neonatal hypoglycemia. The primary aims of the study were to assess the incidence and clinical features of anomalous late-onset FGR, and to compare the perinatal outcome of such cases with that of fetuses with non-anomalous late-onset FGR. RESULTS: Overall, 1246 pregnancies complicated by late-onset FGR were included in the study, of which 120 (9.6%) were allocated to the anomalous late-onset FGR group. Of these, 11 (9.2%) had a genetic syndrome or aneuploidy, 105 (87.5%) had an isolated structural malformation, and four (3.3%) had a congenital infection. The most frequent structural defects associated with late-onset anomalous FGR were genitourinary malformations (28/105 (26.7%)) and limb malformation (21/105 (20.0%)). Compared with the non-anomalous late-onset FGR group, fetuses with anomalous late-onset FGR had an increased incidence of composite adverse perinatal outcome (35.9% vs 58.3%; P < 0.01). Newborns with anomalous, compared to those with non-anomalous, late-onset FGR showed a higher frequency of need for respiratory support at birth (25.8% vs 9.0%; P < 0.01), intubation (10.0% vs 1.1%; P < 0.01), NICU admission (43.3% vs 22.6%; P < 0.01) and longer hospital stay (median, 24 days (range, 4-250 days) vs 11 days (range, 2-59 days); P < 0.01). CONCLUSIONS: Most pregnancies complicated by anomalous late-onset FGR have structural malformations rather than genetic abnormality or infection. Fetuses with anomalous late-onset FGR have an increased incidence of complications at birth and NICU admission and a longer hospital stay compared with fetuses with isolated late-onset FGR. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Recém-Nascido Pequeno para a Idade Gestacional , Ultrassonografia Pré-Natal , Feminino , Gravidez , Recém-Nascido , Humanos , Lactente , Estudos de Coortes , Incidência , Retardo do Crescimento Fetal , Idade Gestacional , Feto , Aneuploidia
16.
Ultrasound Obstet Gynecol ; 59(3): 296-303, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34405927

RESUMO

OBJECTIVE: To evaluate the methodology of studies reporting reference ranges for fetal brain structures on magnetic resonance imaging (MRI). METHODS: MEDLINE, EMBASE, CINAHL and the Web of Science databases were searched electronically up to 31 December 2020 to identify studies investigating biometry and growth of the fetal brain and reporting reference ranges for brain structures using MRI. The primary aim was to evaluate the methodology of these studies. A list of 26 quality criteria divided into three domains, including 'study design', 'statistical and reporting methods' and 'specific aspects relevant to MRI', was developed and applied to evaluate the methodological appropriateness of each of the included studies. The overall quality score of a study, ranging between 0 and 26, was defined as the sum of scores awarded for each quality criterion and expressed as a percentage (the lower the percentage, the higher the risk of bias). RESULTS: Fifteen studies were included in this systematic review. The overall mean quality score of the studies evaluated was 48.7%. When focusing on each domain, the mean quality score was 42.0% for 'study design', 59.4% for 'statistical and reporting methods' and 33.3% for 'specific aspects relevant to MRI'. For the 'study design' domain, sample size calculation and consecutive enrolment of women were the items found to be at the highest risk of bias. For the 'statistical and reporting methods' domain, the presence of regression equations for mean and SD for each measurement, the number of measurements taken for each variable and the presence of postnatal assessment information were the items found to be at the highest risk of bias. For the 'specific aspects relevant to MRI' domain, whole fetal brain assessment was not performed in any of the included studies and was therefore considered to be the item at the highest risk of bias. CONCLUSIONS: Most of the previously published studies reporting fetal brain reference ranges on MRI are highly heterogeneous and have low-to-moderate quality in terms of methodology, which is similar to the findings reported for ultrasound studies. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Gravidez , Valores de Referência , Ultrassonografia
17.
Ultrasound Obstet Gynecol ; 59(1): 93-99, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34309926

RESUMO

OBJECTIVES: To describe a newly developed machine-learning (ML) algorithm for the automatic recognition of fetal head position using transperineal ultrasound (TPU) during the second stage of labor and to describe its performance in differentiating between occiput anterior (OA) and non-OA positions. METHODS: This was a prospective cohort study including singleton term (> 37 weeks of gestation) pregnancies in the second stage of labor, with a non-anomalous fetus in cephalic presentation. Transabdominal ultrasound was performed to determine whether the fetal head position was OA or non-OA. For each case, one sonographic image of the fetal head was then acquired in an axial plane using TPU and saved for later offline analysis. Using the transabdominal sonographic diagnosis as the gold standard, a ML algorithm based on a pattern-recognition feed-forward neural network was trained on the TPU images to discriminate between OA and non-OA positions. In the training phase, the model tuned its parameters to approximate the training data (i.e. the training dataset) such that it would identify correctly the fetal head position, by exploiting geometric, morphological and intensity-based features of the images. In the testing phase, the algorithm was blinded to the occiput position as determined by transabdominal ultrasound. Using the test dataset, the ability of the ML algorithm to differentiate OA from non-OA fetal positions was assessed in terms of diagnostic accuracy. The F1 -score and precision-recall area under the curve (PR-AUC) were calculated to assess the algorithm's performance. Cohen's kappa (κ) was calculated to evaluate the agreement between the algorithm and the gold standard. RESULTS: Over a period of 24 months (February 2018 to January 2020), at 15 maternity hospitals affiliated to the International Study group on Labor ANd Delivery Sonography (ISLANDS), we enrolled into the study 1219 women in the second stage of labor. On the basis of transabdominal ultrasound, they were classified as OA (n = 801 (65.7%)) or non-OA (n = 418 (34.3%)). From the entire cohort (OA and non-OA), approximately 70% (n = 824) of the patients were assigned randomly to the training dataset and the rest (n = 395) were used as the test dataset. The ML-based algorithm correctly classified the fetal occiput position in 90.4% (357/395) of the test dataset, including 224/246 with OA (91.1%) and 133/149 with non-OA (89.3%) fetal head position. Evaluation of the algorithm's performance gave an F1 -score of 88.7% and a PR-AUC of 85.4%. The algorithm showed a balanced performance in the recognition of both OA and non-OA positions. The robustness of the algorithm was confirmed by high agreement with the gold standard (κ = 0.81; P < 0.0001). CONCLUSIONS: This newly developed ML-based algorithm for the automatic assessment of fetal head position using TPU can differentiate accurately, in most cases, between OA and non-OA positions in the second stage of labor. This algorithm has the potential to support not only obstetricians but also midwives and accoucheurs in the clinical use of TPU to determine fetal occiput position in the labor ward. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Inteligência Artificial , Apresentação no Trabalho de Parto , Complicações do Trabalho de Parto/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Área Sob a Curva , Feminino , Feto/diagnóstico por imagem , Feto/embriologia , Cabeça/diagnóstico por imagem , Cabeça/embriologia , Humanos , Segunda Fase do Trabalho de Parto , Gravidez , Estudos Prospectivos
18.
Phys Med ; 89: 11-19, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34343762

RESUMO

PURPOSE: To propose a multivariate multi-step framework for a systematic assessment of the estimation reliability and discriminability of Intravoxel Incoherent Motion (IVIM) model parameters. METHODS: Monte-Carlo simulations were generated on a range of SNRs and in different IVIM combinations considering: i) a dense discretization with 24 b-values; ii) a discretization with 9 b-values. A state-of-the-art Bayesian fitting method was adopted. The framework assessed: i) the best model between mono- and bi-exponential, through the BIC index; ii) the fitting accuracy; iii) the power in discriminating two different IVIM parameters distributions of estimated coefficients, using a multivariate test. Exemplificative oncologic cases were also presented. RESULTS: The bi-exponential fitting was reliable for perfusion fraction higher than 5%, with high accuracy in D estimation, acceptable error for f, but high uncertainty in D*. The discrimination of two distributions is generally feasible if differences in D values (at least 0.3 x10-3 mm2/s) are present; in the case of similar D values, a minimal difference of 5% in f can be discriminated just in case of balanced sample size and dense b-values discretization, whereas the impact of D* is quite negligible. These results were also supported by clinical examples. CONCLUSIONS: IVIM model is generally accurate in estimating diffusion, but uncertainties related to perfusion estimation are not negligible and compromise the discrimination power when different populations should be differentiated. The proposed framework should be adopted as interpretative guidelines to better understand when IVIM model applied on real data can provide reliable findings.


Assuntos
Imagem de Difusão por Ressonância Magnética , Teorema de Bayes , Movimento (Física) , Reprodutibilidade dos Testes , Razão Sinal-Ruído
19.
Ultrasound Obstet Gynecol ; 57(5): 687-697, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33724545

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a zoonotic coronavirus that crossed species to infect humans, causing coronavirus disease 2019 (COVID-19). Despite a potentially higher risk of pregnant women acquiring SARS-CoV-2 infection compared with the non-pregnant population (particularly in some ethnic minorities), no additional specific recommendations to avoid exposure are needed in pregnancy. The most common clinical symptoms and laboratory signs of SARS-CoV-2 infection in pregnancy are fever, cough, lymphopenia and elevated C-reactive protein levels. Pregnancy is associated with a higher risk of severe SARS-CoV-2 infection compared with the non-pregnant population, including pneumonia, admission to the intensive care unit and death, even after adjusting for potential risk factors for severe outcomes. The risk of miscarriage does not appear to be increased in women with SARS-CoV-2 infection. Evidence with regards to preterm birth and perinatal mortality is conflicting, but these risks are generally higher only in symptomatic, hospitalized women. The risk of vertical transmission, defined as the transmission of SARS-CoV-2 from the mother to the fetus or the newborn, is generally low. Fetal invasive procedures are considered to be generally safe in pregnant women with SARS-CoV-2 infection, although the evidence is still limited. In pregnant women with COVID-19, use of steroids should not be avoided if clinically indicated; the preferred regimen is a 2-day course of dexamethasone followed by an 8-day course of methylprednisolone. Non-steroidal anti-inflammatory drugs may be used if there are no contraindications. Hospitalized pregnant women with severe COVID-19 should undergo thromboprophylaxis throughout the duration of hospitalization and at least until discharge, preferably with low molecular weight heparin. Hospitalized women who have recovered from a period of serious or critical illness with COVID-19 should be offered a fetal growth scan about 14 days after recovery from their illness. In asymptomatic or mildly symptomatic women who have tested positive for SARS-CoV-2 infection at full term (i.e. ≥ 39 weeks of gestation), induction of labor might be reasonable. To date, there is no clear consensus on the optimal timing of delivery for critically ill women. In women with no or few symptoms, management of labor should follow routine evidence-based guidelines. Regardless of COVID-19 status, mothers and their infants should remain together and breastfeeding, skin-to-skin contact, kangaroo mother care and rooming-in throughout the day and night should be practiced, while applying necessary infection prevention and control measures. Many pregnant women have already undergone vaccination, mostly in the USA where the first reports show no significant difference in pregnancy outcomes in pregnant women receiving SARS-CoV-2 vaccination during pregnancy compared with the background risk. Vaccine-generated antibodies were present in the umbilical cord blood and breast milk samples of pregnant and lactating women who received the mRNA COVID-19 vaccine. Based on the available limited data on the safety of the COVID-19 vaccine in pregnancy, it seems reasonable to offer the option of vaccination to pregnant women after accurate counseling on the potential risk of a severe course of the disease and the unknown risk of fetal exposure to the vaccine. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Vacinas contra COVID-19/uso terapêutico , COVID-19/prevenção & controle , Aconselhamento/estatística & dados numéricos , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Educação de Pacientes como Assunto/estatística & dados numéricos , Complicações Infecciosas na Gravidez/prevenção & controle , Adulto , Feminino , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez/epidemiologia
20.
Tech Coloproctol ; 25(3): 319-331, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33459969

RESUMO

BACKGROUND: The aim of this study was to quantify the incidence of short-term postoperative complications and functional disorders at 1 year from transanal endoscopic microsurgery (TEM) for rectal neoplasms, to compare patients treated with TEM alone and with TEM after preoperative chemoradiotherapy (CRT) and to analyse factors influencing postoperative morbidity and functional outcomes. METHODS: A retrospective study was conducted on all patients treated with TEM for rectal neoplasms at our institution in January 2000-December 2017. Data from a prospectively maintained database were retrospectively analysed. Patients were divided into two groups: adenoma or early rectal cancer (no CRT group) and locally advanced extraperitoneal rectal cancer with major or complete clinical response after preoperative CRT (CRT group). Short-term postoperative mortality and morbidity and the functional results at 1 year were recorded. The two groups were compared, and a statistical analysis of factors influencing postoperative morbidity and functional outcomes was performed. Functional outcome was also evaluated with the low anterior resection syndrome (LARS) score (0-20 no LARS, 21-29 minor LARS and 30-42 major LARS). RESULTS: One hundred and thirteen patients (71 males, 42 females, median age 64 years [range 41-80 years]) were included in the study (46 in the CRT group). The overall postoperative complication rate was 23.0%, lower in the noCRT group (p < 0.001), but only 2.7% were grade ≥ 3. The most frequent complication was suture dehiscence (17.6%), which occurred less frequently in the noCRT group (p < 0.001). At 1 year from TEM, the most frequent symptoms was urgency (11.9%, without significant differences between the CRT group and the noCRT group); the noCRT group experienced a lower rate of soiling than the CRT group (0% vs. 7.7%; p: 0.027). The incidence of LARS was evaluated in 47 patients from May 2012 on and was 21.3% occurring less frequently in the noCRT group (10% vs. 41.2%; p: 0.012). Only 6.4% of the patients evaluated experienced major LARS. In multivariate analysis, preoperative CRT significantly worsened postoperative morbidity and functional outcomes. CONCLUSIONS: TEM is a safe procedure associated with only low risk of severe postoperative complications and major LARS. Preoperative CRT seems to increase the rate of postoperative morbidity after TEM and led to worse functional outcomes at 1 year after surgery.


Assuntos
Neoplasias Retais , Microcirurgia Endoscópica Transanal , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimiorradioterapia/efeitos adversos , Feminino , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Neoplasias Retais/cirurgia , Estudos Retrospectivos , Síndrome , Microcirurgia Endoscópica Transanal/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...